Part Number : H7112 | NSN : 5950-00-199-22975950001992297 |
Item Name : Transformer Power | Manufacturer : Merit Coil And Transformer Corp |
CAGE Code : 74042 | FSC : FSC5950 Coils and Transformers |
NIIN : 001992297 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 5.250 INCHES NOMINAL |
ADAT | BODY WIDTH | 5.000 INCHES NOMINAL |
ADAU | BODY HEIGHT | 5.000 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 1.5 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 6.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 117.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 12.70 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 14.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 6 TAB, SOLDER LUG |
Don't Forget That We Can Give You a Quote for Parts Within 15 Minutes If You Fill Out The Instant RFQ Form.
Request for Quote