Part Number : 1118629 | NSN : 2920-00-640-75192920006407519 |
Item Name : Regulator Engine Ge | Manufacturer : General Motors Llc |
CAGE Code : 16764 | FSC : FSC2920 Engine Electrical System Components Nonaircraft |
NIIN : 006407519 |
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
2920-00-640-7519 Item Description: Regulator Engine Ge | 2920 | 006407519 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
1118629 | 2 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARA | TERMINAL QUANTITY | 3 |
AARB | TERMINAL TYPE | SCREW |
ABTB | MOUNTING HOLE DIAMETER | 0.328 INCHES NOMINAL |
ABTD | MOUNTING SLOT WIDTH | 0.328 INCHES NOMINAL |
ABVG | MOUNTING SLOT LENGTH | 0.453 INCHES NOMINAL |
ADER | MOUNTING STYLE | TWO PLAIN HOLES TWO SLOTTED HOLES |
ADNY | DISTANCE BETWEEN HOLES ALONG LENGTH | 6.000 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | CORROSION RESISTANT ERR-100 ERR-100 |
ADZC | ENVIRONMENTAL PROTECTION | FUNGUS RESISTANT ERR-100 ERR-100 |
AGBC | SHOCK MOUNT | NOT PROVIDED |
ALBH | RADIO INTERFERENCE SHIELDING | NOT PROVIDED |
ANPP | OUTPUT VOLTAGE RATING IN VOLTS | 28.0 MINIMUM ERR-100 ERR-100 |
ANPP | OUTPUT VOLTAGE RATING IN VOLTS | 29.5 MAXIMUM ERR-100 ERR-100 |
ANYC | SYSTEM VOLTAGE RATING | 24.0 |
ANYD | SYSTEM GROUND POLARITY | NEGATIVE |
ANYE | VOLTAGE REGULATOR UNIT TYPE | WIRE WOUND COIL |
ANYH | VOLTAGE REGULATOR UNIT QUANTITY | 1 |
ANYJ | CURRENT REGULATOR UNIT TYPE | WIRE WOUND COIL |
ANYK | CURRENT REGULATOR UNIT QUANTITY | 1 |
ANYP | OUTPUT CURRENT RATING IN AMPS | 38.0 MINIMUM ERR-100 ERR-100 |
ANYP | OUTPUT CURRENT RATING IN AMPS | 42.0 MAXIMUM ERR-100 ERR-100 |
ANYR | CIRCUIT CONTROL DEVICE TYPE | CUTOUT RELAY |
ANYS | CUT-IN VOLTAGE RATING | 25.0 MINIMUM ERR-100 ERR-100 |
ANYS | CUT-IN VOLTAGE RATING | 27.0 MAXIMUM ERR-100 ERR-100 |
ANYX | CUTOUT VOLTAGE RATING | 14.0 MINIMUM ERR-100 ERR-100 |
ANYX | CUTOUT VOLTAGE RATING | 17.0 MAXIMUM ERR-100 ERR-100 |
ANYZ | CUTOUT CURRENT RATING IN AMPS | 24.0 MAXIMUM ERR-100 ERR-100 |
ANYZ | CUTOUT CURRENT RATING IN AMPS | 8.0 MINIMUM ERR-100 ERR-100 |
ANZB | REVERSE CURRENT OVERLOAD CIRCUIT BREAKER | NOT INCLUDED |
ANZC | FIELD RELAY UNIT | NOT INCLUDED |
ANZE | TERMINAL ENCASEMENT | NOT ENCASED |
APAT | CENTER TO CENTER DISTANCE BETWEEN SLOTTED HOLES ALONG LENGTH | 6.000 INCHES NOMINAL |
APAW | CENTER TO CENTER DISTANCE BETWEEN SLOTTED HOLES AND PLAIN HOLES ALONG WIDTH | 5.315 INCHES NOMINAL |