Part Number : 21092 | NSN : 5950-00-133-42915950001334291 |
Item Name : Reactor | Manufacturer : Freed Transformer Company |
CAGE Code : 73386 | FSC : FSC5950 Coils and Transformers |
NIIN : 001334291 |
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-133-4291 Item Description: Reactor | 5950 | 001334291 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
21092 | 6 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ACYF | INDUCTANCE TYPE | FIXED |
ACYV | INDUCTANCE RATING | 1.25 HENRY NOMINAL SINGLE COMPONENT SINGLE WINDING |
ACZB | FREQUENCY RATING | 114.0 HERTZ MINIMUM SINGLE COMPONENT AND 126.0 HERTZ MAXIMUM SINGLE COMPONENT |
ADAQ | BODY LENGTH | 1.500 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.250 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.890 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 85.0 DEG CELSIUS |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.910 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKDX | WINDING QUANTITY | 1 SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
AXGY | MOUNTING METHOD | BRACKET SINGLE GROUP AND THREADED HOLE SINGLE GROUP |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 60.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 50.000 SINGLE COMPONENT SINGLE WINDING |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TURRET |
Don't Forget That We Can Give You a Quote for Parts Within 15 Minutes If You Fill Out The Instant RFQ Form.
Request for Quote