Part Number : TCL-1-HW-ST-1-2-IN-ODF-X-5-8-ODF | Alternate P/N : TCL1HWST12INODFX58ODF |
NSN : 4820-00-983-59324820009835932 | Item Name : Valve Expansion |
Manufacturer : Cecom Lr Center | CAGE Code : 97403 |
FSC : FSC4820 Valves Nonpowered | NIIN : 009835932 |
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
4820-00-983-5932 Item Description: VALVE,EXPANSION | 4820 | 009835932 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
TCL1HW | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAFZ | BODY MATERIAL | BRASS |
AAQL | BODY STYLE | SINGLE CONNECTION, STRAIGHT FLOW |
ABJH | TEMP RATING | 100.0 DEG FAHRENHEIT |
ACKL | MEDIA FOR WHICH DESIGNED | REFRIGERANT 22 |
ACKM | FIRST END CONNECTION TYPE | UNTHREADED INTERNAL TUBE |
ACKN | FIRST END STYLE DESIGNATOR | PLAIN |
ACLH | FIRST END OUTSIDE DIAMETER TUBE ACCOMMODATED | 0.625 INCHES NOMINAL |
ACLR | SECOND END RELATIONSHIP WITH FIRST END | NOT IDENTICAL |
ACLS | SECOND END CONNECTION TYPE | UNTHREADED INTERNAL TUBE |
ACLT | SECOND END STYLE DESIGNATOR | PLAIN |
ACMP | SECOND END OUTSIDE DIAMETER TUBE ACCOMMODATED | 0.500 INCHES NOMINAL |
ACSH | SEAT MATERIAL | BRASS |
ADQU | FLOW CONTROL DEVICE | CAGE |
ADQV | FLOW CONTROL DEVICE MATERIAL | BRASS |
ADQZ | END CONNECTION QUANTITY | 2 |
AEVT | CAPILLARY TUBE LENGTH | 58.000 INCHES MINIMUM AND 62.000 INCHES MAXIMUM |
AEVU | BULB LENGTH | 3.060 INCHES NOMINAL |
AEVV | BULB DIAMETER | 0.623 INCHES MINIMUM AND 0.639 INCHES MAXIMUM |
AFKK | VALVE EXPANSION CONTROL TYPE | THERMOSTATIC |
AFKL | VALVE EVAPORATOR TEMP RANGE DESIGNATION | HIGH |
AFKM | VALVE PRESSURE LIMITING DEVICE | INCLUDED |
AFKN | VALVE PRESSURE LIMITING DEVICE SETTING | 100.0 POUNDS PER SQUARE INCH GAGE |
AFKQ | BULB MEDIA TYPE | REFRIGERANT 22 |
AFKR | BULB MOUNTING METHOD | CLAMP |
AFKU | VALVE EQUALIZER LOCATION | INTERNAL |
AGUB | REFRIGERATION CAPACITY IN BTU PER HOUR | 12.0 |
TEST | TEST DATA DOCUMENT | 97403-13213E0601 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING D |