Part Number : 5D0001-1 | Alternate P/N : 5D00011 |
NSN : 5925-01-380-72835925013807283 | Item Name : Circuit Breaker |
Manufacturer : Boeing Company The | CAGE Code : 88277 |
FSC : FSC5925 Circuit Breakers | NIIN : 013807283 |
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-380-7283 Item Description: Circuit Breaker | 5925 | 013807283 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
5d0001-1 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
THSD | Thread Series Designator | UNS |
AAQL | Body Style | SINGLE POLE TYPE |
CQXF | Inclosure Protection Type For Which Designed | VIBRATION RESISTANT AND SHOCK RESISTANT AND SAND RESISTANT AND DUSTTIGHT AND CORROSION RESISTANT AND HUMIDITY RESISTANT AND EXPLOSION PROOF |
AFJN | Fragility Factor | MODERATELY RUGGED |
PKWT | Unpackaged Unit Weight | 29.0 GRAMS |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
BBRJ | Special Handling Feature | MAGNETIC |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 120.0 AC ALL LOCATIONS |
ABXD | Bushing Length | 0.359 INCHES NOMINAL |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 800.0 AC ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 2 TAB W/SCREW |
ADAT | Body Width | 0.562 INCHES NOMINAL |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
AKPX | Pole Quantity | 1 |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 145.0 ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPRT | Manual Actuator Type And Quantity | 1 PUSH-PULL |
CPRX | Actuator Position Designation | AT POLE ONE |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
ADTV | Case Material | PLASTIC |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
MRC | Decoded Requirement | Clear Text Reply |
AJWX | Mounting Surface To Terminal End Distance | 1.287 INCHES MINIMUM AND 1.317 INCHES MAXIMUM |
ADAQ | Body Length | 0.750 INCHES NOMINAL |
CQJX | Nominal Thread Size | 0.438 INCHES |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.593 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 1.0 AMPERES AC ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CMLP | Thread Quantity Per Inch | 32 |
CPRW | Actuator Function | TRIP-RESET |
Don't Forget That We Can Give You a Quote for Parts Within 15 Minutes If You Fill Out The Instant RFQ Form.
Request for Quote